TY - JOUR
T1 - A comparison of the FitroDyne and GymAware rotary encoders for quantifying peak and mean velocity during traditional multi-jointed exercises
AU - Fernandes, John
AU - Lamb, Kevin L.
AU - Clark, C. C. T.
AU - Moran, Jason
AU - Drury, Ben
AU - Garcia-Ramos, Amador
AU - Twist, Craig
PY - 2021/6/1
Y1 - 2021/6/1
N2 - The FitroDyne and GymAware rotary encoders are being increasingly used in resistance training to monitor movement velocity, but how closely their velocity outcomes agree is unknown. Consequently, this study aimed to determine the level of agreement between the FitroDyne and GymAware for the assessment of movement velocity in three resistance training exercises. Fifteen males performed three repetitions of bench press, back squat and bent-over-row exercises at 10% one repetition maximum increments (from 20 to 80%). For each repetition, the FitroDyne and GymAware recorded peak and mean barbell velocity (cm.s-1). Though strongly correlated (r = 0.79 to 1.00), peak velocity values for the GymAware were significantly lower than the FitroDyne for all exercises and loads. Importantly, the random errors between the devices, quantified via Bland and Altman's 95% limits of agreement, were unacceptable, ranging from ± 3.8 to 25.9 cm.s-1. Differences in mean velocity were smaller (and non-significant for most comparisons) and highly correlated (r = 0.86 to 1.00) between devices. Notwithstanding smaller random errors than for the peak values, mean values still reflected poor agreement (random errors between ± 2.1 to 12.0 cm.s-1). These findings suggest that the FitroDyne and GymAware cannot record peak or mean velocity with acceptable agreement, and should neither be employed interchangeably nor their data compared.
AB - The FitroDyne and GymAware rotary encoders are being increasingly used in resistance training to monitor movement velocity, but how closely their velocity outcomes agree is unknown. Consequently, this study aimed to determine the level of agreement between the FitroDyne and GymAware for the assessment of movement velocity in three resistance training exercises. Fifteen males performed three repetitions of bench press, back squat and bent-over-row exercises at 10% one repetition maximum increments (from 20 to 80%). For each repetition, the FitroDyne and GymAware recorded peak and mean barbell velocity (cm.s-1). Though strongly correlated (r = 0.79 to 1.00), peak velocity values for the GymAware were significantly lower than the FitroDyne for all exercises and loads. Importantly, the random errors between the devices, quantified via Bland and Altman's 95% limits of agreement, were unacceptable, ranging from ± 3.8 to 25.9 cm.s-1. Differences in mean velocity were smaller (and non-significant for most comparisons) and highly correlated (r = 0.86 to 1.00) between devices. Notwithstanding smaller random errors than for the peak values, mean values still reflected poor agreement (random errors between ± 2.1 to 12.0 cm.s-1). These findings suggest that the FitroDyne and GymAware cannot record peak or mean velocity with acceptable agreement, and should neither be employed interchangeably nor their data compared.
U2 - 10.1519/JSC.0000000000002952
DO - 10.1519/JSC.0000000000002952
M3 - Journal Article
SN - 1064-8011
JO - Journal of Strength and Conditioning Research
JF - Journal of Strength and Conditioning Research
ER -